Model | FS-OG-20 | FS-OG-40 | FS-OG-60 | FS-OG-80 | ||||
Rated Charge Current | 10A | 20A | 30A | 40A | 50A | 60A | 80A | |
System voltage | 50V | |||||||
Maximum PV open circuit voltage | ≤30mA | |||||||
Loop voltage drop | ≤0.3V | |||||||
USB Output | 5V/2A×4 | |||||||
Temperature compensation | -4mV/℃/2V(25℃) | |||||||
Working temperature range | -20℃~+50℃ | |||||||
Protection category | IP32 | |||||||
Humidity | 95%,no-condensing | |||||||
Terminals | 8AWG/10mm2 | 8AWG/16mm2 | 4AWG/25mm2 | |||||
Mounting hole size | 158×68mm Φ 6mm | 190×69mm Φ 5mm | 190×104mm Φ 5mm | |||||
Product size | 168×88×36mm | 200×106×47mm | 200×131.6×62mm | |||||
Weight | 0.22Kg | 0.4Kg | 0.73Kg | 0.79Kg |
FSOLAR ORANGE PWM:
Major Functions:
l System voltage of battery 12V/24V or 12V/24V/36V/48V automatic recognition;
l Intelligent 4 stages PWM charging: Bulk, Absorption, Equalize, Float;
l LCD display with Back-lighting shows device’s operating data and working condition;
l Humanized simple button operation; Adjustable charge-discharge control parameters;
l Support more kinds of battery: Lead-acid battery (Sealed, Gel, Flooded)
l Multiple load control modes: 24Hours Working Control, Light Control, Light and Dual Time Control;
l Automatic temperature compensation and accumulated function of charge and discharge KWH;
l Double USB output 5V/2A;
l Perfect electronic protections.
Protections:
l Solar Panel Reverse-Polarity:
If the solar panel is connected with controller in reversed polarity, controller will not be damaged and will work as normal when correctly connected.
l Battery Reverse-Polarity:
If the battery is connected with controller in reversed polarity (solar controller is not connected with solar panel), controller will not be damaged and will work as normal when correctly connected.
l Battery Reverse-Discharge:
Controller is able to protect battery from reversed discharging to solar panel at night.
l Over-Heating Protection:
Once the internal temperature is detected to be higher than a certain value by the controller, it will stop charging the battery and then recharging the battery automatically after the temperature drop to a certain value.
l Battery Over-Current:
Controller will stop charging when excess current is detected from the solar panel, and recharging automatically after 2 min.
l Load Over-Load:
The load will be turned off when the output current of load exceeds its rated current for a while, and turned on automatically after 2 min.
l Load Short-Circuit:
Controller will be in protection state when the load is short circuit, and
recharging automatically after 2 min.
l Battery Low-Voltage:
Controller will turn off the load when the battery voltage is lower than the value preset for low-voltage disconnection, and turn on the load when the battery
voltage reaches the value preset for low-voltage re-connection. The value for
low-voltage disconnection and low-voltage re-connection can be set by users in a certain range.
l Battery Over-Voltage:
Controller will turn off the load when the battery voltage is higher than the value preset for over-voltage protection, and turn on the load when the battery voltage is 1V lower than the value preset for over-voltage protection.
l Lightning Protection:
The lightning protection function of controller is limited and it is recommended to install devices for lightning protection on the input side to increase system reliability.